<LOGO>
FM Transmitter Measurement Report
Created: 2023-11-22 09-34-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.40 MHz 3/5, 39 dBuV VIBRA fm
Pilot RDS Phase Difference
6.7 kHz 2.4 kHz 44 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
14 kHz 72 kHz 1783 0,1122
Modulation Power
Limit Measuring Tolerance
9,0 dBr 1,0 dBr
MIN AVE MAX % above 10,0 dBr
5,1 dBr 7,27 dBr 8,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VIBRA fm" F560 9 (Varied) 1 0 1 1 --:--
RT
" I - "
AF EON
90.3, 93.4, 101.7, 102.0, 102.1 MHz -
FM Scope Station: 93.40 MHz, signal: 3/5 (39 dBuV) Max at: 72 kHz MIN: 14 kHz % above 75 kHz: 0,1122 Acquired: 2023/11/22 9:33:37 Total samples: 1783 Equivalent time: 0:01:29 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 20 40 60
FM Scope MAX: 8,5 dBr MIN: 5,1 dBr AVE: 7,27 dBr % above 10,0 dBr: 0,0 Last value: 8,2 dBr (2023/11/22 9:33:35) Station: 93.40 MHz, signal: 3/5 (39 dBuV) 09:20 09:22 09:24 09:26 09:28 09:30 09:32 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality